Home Contact Tel. TOP
Polyvinyl chloride insulation Sheathed controlcable


Polyvinyl chloride insulation Sheathed controlcable

Model and Name

[KVV] Copper core PVC insulated PVC sheathed control cable
[KWP2-22] Copper core PVC insulated PVC sheathed braided shielding control flexible cable
[KVV22] Copper core PVC insulated PVC steel tape armored control cable
[KVVR] Copper core PVC insulated PVC sheathed control cable
[KVV32] Copper core PVC insulated PVC fine steel wire armored control cable
[KVVRP] Copper core PVC insulated ethylene sheathed braided shielded control cable
[KVVP] Copper core PVC insulated PVC sheathed copper tape shielded steel tape armored control cable

Product Features and Applications

• This product is manufactured by equivalently adopting IEC227 standard;

• Clear product identification marks are printed on the cable outer sheath. Insulated cores are coded for sequence distinction;

• The long-term operating temperature of the cable is 70℃;

• Conductors adopt Type A and Type B, Type A is single core, Type B is made of 7 stranded wires;

• The braided shield has strong anti-interference performance.

Manufacturing Standards

• This product is manufactured in accordance with GB/T127061-2008 or C60502 standard, and can also be produced to other standards as required by customers. In addition to the above standards, the flame retardant performance of flame-retardant cables is divided into three different flame retardant categories A, B and C in accordance with GB/T18380.3-2001 standard. Category A has the best flame retardant performance, and customers can select it as required.

• In addition to the above standards, the flame retardant performance of flame-retardant cables is divided into four different flame retardant categories A, B, C and D in accordance with GA306.1 standard. Category A has the best flame retardant performance, and customers can select it as required.

• The fire-resistant performance of fire-resistant cables complies with GA306.1 standard (950C-1000C/900min). Customers can select according to application occasions and requirements.

Product Service Characteristics

• Rated voltage Uo/U is 450/750V

• The long-term allowable operating temperature of cable conductors is 70°C.

• The cable laying temperature shall not be lower than 0°C. The recommended allowable bending radii are as follows: non-armoured cables shall be not less than 6 times the cable outer diameter; armoured or steel tape shielded electric cables shall be not less than 12 times the cable outer diameter; flexible cables with shielding layer structure shall be not less than 6 times the cable outer diameter.